KAEFER’s Test Laboratories

The KAEFER climatic chamber.

The KAEFER test laboratory has an exceptional range of equipment at its disposal, including a walk-in climatic chamber for example. A temperature range going as low as -70°C is a unique feature in this 15m³ chamber.

A further advantage of the KAEFER system is its ability to simulate temperature, air humidity and internal pressure of samples simultaneously. This combination was only made possible by fitting the climatic chamber with further devices put together and configured by KAEFER engineers.

The climatic chamber allows us to test several samples simultaneously if necessary. It can maintain ambient conditions constant or vary them in temperature and humidity as required over any desired period of time.

The climatic chamber can also perform shock tests with temperature drops of up to 100 K within 10 minutes. All test parameters and results are recorded and stored in digital form. All measurements are performed using sensors calibrated by accredited laboratories, guaranteeing extreme accuracy.

For tests of smaller objects even constant climatic cabinets are available.

Gyna Galvis Diaz

Gyna Galvis Diaz

Corporate Operations Excellence

+49 421 6109 467

Technical data of the climatic chamber

Functions

  • Airflow control
  • Extraction of waste air from the air conditioning chamber at ceiling level
  • Air inlet to the air conditioning chamber at floor level
  • Humidification through steam humidifier
  • Sensors: temperature sensors of type PT 100, DIN 43 760, Class A
  • Capacitive humidity sensors

Test procedures / Documentation

  • Entry of test programs
  • Graphic program preview
  • Graphic display of test procedure. Curves of temperature and relative humidity over time

Dimensions

  • Testing volume ca. 15 m3
  • Test chamber dimensions 2,500 x 3,000 x 2,000 (w/d/h)
  • Doorway clearance 2,500 x 2,000 mm (w/h)

Performance range of climatic tests

  • Temperature range +10°C to +95°C
  • Humidity range 10 % to 95 % rel. humidity
  • Dew point range +5°C to +89°C
  • Temperature deviation ±0.5 K at any defined point in time
  • Humidity deviation ±1 - 3 % rel.hum. at any defined point in time

at an outside temperature of +25°C

Technical features

  • Adherence to current CE and EMC regulations
  • 3 pipe penetrations of 125 mm dia
  • Door fitted with large viewing window
  • Illuminated testing chamber
  • U-rail sections mounted 500 mm apart on left and right side of testing space to allow for fastening of carrying and charging equipment
  • Floor load bearing capacity 10,000 N/m²
  • Wheel load 600 N/wheel (contact patch size 4 cm²)
  • Asymmetrically divided (1/3 to 2/3) double wing door (1000 + 1500 mm)

Performance range of temperature tests

  • Temperature range -70°C to +120°C
  • Temperature deviation ±0.5 at ±1 K at any defined point in time
  • Rate of temperature change 10 K/min

at an outside temperature of +25°C

Test standards

In the area of environmental simulation, we can cover a wide range of tests. Additionally changes in temperature of up to 10K/min are achievable.

Please take a look at possible test standards:

Constant climate

Standards

Climatic cabinet

Climatic chamber

DIN 40046, sheet 2 x x
DIN 40046, sheet 5, test C  x x
DIN 50014 x x
IEC 68-2-3, test Ca x x
VG 95210, sheet 4, test 103 B x x
MIL-STD 202 E, method 103 B x x
VG 95332, sheet 5 x x
DIN/IEC 68-2-56 x x

 

KAEFER climatic chamber
Leakage test of a sample after testing in KAEFER’s climatic chamber

  
  

 

 

Alternating climate

Standards

Climatic cabinet

Climatic chamber

DIN/IEC 68-2-30 DB type 1   - x
DIN/IEC 68-2-30 DB type 2  - x
DIN/IEC 68-2-38  - x
DIN EN 60068-2-14 test Nb   - x
DIN 40046, sheet 6 and sheet 31   - x
IEC 68-2-4, test D   - x
BS 2001, part 2.1 test Da  - x
VG 95210, sheet 7, method 106 C  - x
DIN 40046, sheet 101   - x
DIN 50016  - x
MIL-E 5272 test 4.4  - x
MIL-T 5422 E, part 4.4  - x
MIL-STD 202 E, method 106 D  - x
MIL-STD 331 A, method 1.05.1  - x
MIL-STD 750 B, method 1021.1  - x
MIL-STD 810, method 507 proc. 1  - x
MIL-STD 810, method 507 proc. 2  - x
MIL-STD 810, method 507 proc. 3  - x
MIL-STD 883C method 1004.4  - x